Ping the Manager from the Sensor to determine if your configuration settings to this point have
successfully established the Sensor on the network. At the prompt, type: ping <manager IP
address>.
If the ping is successful, continue with the following steps. If not, type show to verify your
configuration settings and check that the information is correct.
j
Set the shared secret key value for the Sensor. At the prompt, type: set sensor
sharedsecretkey.
The Sensor then prompts you to enter the shared key value and confirm the same.
This value is used to establish a trust relationship between the Sensor and the
Manager. The secret key value can be between 8 and 25 characters of any ASCII text.
The shared key value is case-sensitive.
Make sure the value matches the shared secret key value you provided in the Manager
interface.
k
To verify the configuration information, type show. Check that all information is correct.
l
To exit the session, type exit.
8 Verify successful installation
A handshake process begins between the Sensor and the Manager. The devices will take a few
seconds to establish communication.
Perform the following steps to verify successful communication between the Sensor and the Manager.
a
In the Sensor CLI, type: status.
The status report appears